Balboa vs501z error codes. VS501Z instructions manual.


Balboa vs501z error codes Spa controller kit. This weekend the control panel started registering code HL (Difference between temperature sensors and a possible flow problem) and eventually LF (persistent Low flow problems) The heater shuts off and the temperature d https://hottubpartsofamerica. --Temperature unknown After the pump has been running for two minutes, the temperature will be displayed. Page 2 54377-02_97_A System Revision History Balboa 500Z-Series Operation Guide This document covers VS and GS systems 500Z through 521Z with Balboa Panels VL200 through VL406. balboa-instruments. 8°C) In the Heater and Spa Functions are Disabled. This comprehensive guide serves as your definitive resource, navigating the intricacies of the VS501Z manual and empowering 53605 - Sensor Assy, Balboa M7™, 12" Temp/Hi Limit, 1/4"dia, 2-pin New, Featured, & Special Pricing Items The Spa Dragon - Monitoring & Notification, Freeze Protection & Backup Heating System - TSD The Balboa VS501Z is a basic spa pack in the Balboa VS series that can control 1 two speed pump and an additional 1 speed pump or blower if needed. It quickly shuts off. There is Not Enough Water Flow through the Heater to carry the Heat Away from the Heating Element. Here is a direct link to the user manuals specifically the VS500z series VL200, VL401, and VL403 controllers. Follow action required for “HL” message. 5KW heater for colder Canadian climates. Something is wrong with the wiring. pdf 07/05/2006 9XcYfX @ejkild\ekj Jpjk\d GE ,+*. Questions about pool repair? Ask an Expert online. Diagnostic Messages (balboa-instruments. On a spa with a pump suction blockage switch, the vacuum switch has closed indicating that there has been a suction problem or an entrapment avoided. Operates pump, blower, and light. Power to the spa has been cut off. com Temp Control (80°F - 104°F / 26°C - 40°C) The last measured water temperature is constantly displayed. On panels with a single “Temp” or “Set” button, to display the set temperature, press the button once. Balboa vs500z manual advertisement Scroll to page 2 of 8 advertisement Thank you for your participation! * Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project VS501Z Hot Sheet - Balboa Water Group 54379-03, VSP-VS501Z-CCAJ 54368- The VS Series Hot Tub Control Systems were designed using Balboa's patented M7 temperature and flow sensor technology and a new universal control platform. If there is no display, reconnect the initially disconnected cable and instead disconnect the Pool and Hot Tub Depot 195 Exeter Rd F, London, ON N6L 1A4, Canada Hi, In my refurbished spa I installed Balboa VS501Z controller with Laing E14 single speed circulating pump. Check for Water Level, Flow Restrictions, Closed Valves, Air Bubbles, and Pump Prime, or Continue for a Detailed Test Procedure. Accurate Pool & Spa Services, llc Follow Balboa; Bullfrog; Caldera Spas; Cal Spas; Hot Springs; Marquis Spas; Master Spas; Jacuzzi; Sundance; Aqua-flo; Pleatco; A. The Spa is Operating in "Priming" (Pr) Mode. Turn OFF the Power to the System and Turn it back ON again to put System into Priming Mode. James. Last night I noticed that the remote temp sensor was reading about 70 degrees, I wasn't too worried as we turn the temp down to 80 degrees during the week and only filter/heat 4 hours per day (2each 2 hour cycles). Controller Balboa VS501Z Installation Instructions 4 pages. 5KW Flo-Thru Heater, P/N G5152 it is REQUIRED by the National Electric Code to install an external GFCI for safety and protection. Now it has stopped working altogether. Filter Time – This number indicates the total amount of time that the filter has been running. In this condition, an attempt is made to trip the GFCI, which would shut off all power to the spa. Those who are familiar with basic plumbing and electrical skills will find the Balboa controls easy to set up and there is a ton of support info online for Balboa controls. If there is Now an Error Message, select Message Other than CFEor CONFIG ERROR below or contact your Dealer or Service View and Download Balboa VS501Z operation manual online. Change it out to a new Balboa VS501Z pack in April and all worked fine until a month ago. Coupon Codes; Sitemap; Balboa Bluetooth Audio. 1 A A. Dealing with Balboa hot tub error codes can be frustrating, but understanding the possible issues behind each code can make troubleshooting more manageable. C8ZII-230V . The Spa has just been powered up and is in Priming Mode for 4 Minutes. Started getting FL issues in mid May so did the Sensors are a good place to start. The control panel and heater were replaced in March, the pump is a couple of years old and was tested at a motor shop with no issues found, the senors were replaced under warranty, there are no flow issues, a new filter was just put in. The recommended substitute is 50-BP5-500-40-K. 5 Software Version # 43 EPN # 3080 Base PCBA - PN 55514 PCB GS500Z - PN 22015 Rev B Base Panels VL401 (LCD Lite Duplex) – PN 54094 VL402 (LCD Duplex Digital) – PN 54093 Optional Panels VL200 (Mini bath) – PN 52144 Balboa - G6406, BP7 4. My name is XXXXX XXXXX allow me a moment to review your question thoroughly. Heating capability of the VS501Z - power cords included Most listings for this control do not include pump and blower cords, but we DO, this is a $33 value. even if « I power it on or off via the circuit After about 45 Seconds, Check for Error Messages on the Topside Panel Display. pdf 09/24/2007 Template used: 40600_L. php?search_query=m7+sensorThis video is about The Spa Guy showing you how to diagnose a Balboa M7 made by according to National Electrical Code and all local codes and regulations. pdf 08/09/2006 Template used: 40600_E. 120V Conversion Option - Add jumper from Red AC (J32) to White AC (J11) and set DIP switch A10 to ON. 0KW Control Retrofit Kit, TP600 Topside - G6406. Vs501 Series System . Have you taked the filter out and reset the spa to see if went away. With a balboa pack there should be a “test” mode that can be enabled bu a switch on the board. Diag Message on Topside Panel: Warning! Check Error Messages The filter program also controls how the spa heater operates as follows: • Standard filter programs (F0, F1, F2, F3): Heater activates anytime water temperature drops 2 degrees below the set temperature (Jets 1 low speed also activates on non-Circulation Pump models). Spa settings will VS501Z Hot Sheet 54481_01-97_A. Please help! All components are Balboa. Balboa Bluetooth Audio. 2. No Blower. Booster Seat Cushions; Cover Caps & Cover Savers for Cover Lifts; Filter Cleaning Tools; Floating Chemical Dispensers; Fragrance Holders; Glassware, Drink Trays & Spa Caddies Balboa Fault Codes Here are the common spa panel messages that you will encounter with your spa panel. I am regularly getting a "DY" low flow code and have had no luck troubleshooting. Pretty Basic unit. Bluetooth - bba™2 Audio; SpaTouch™ SpaTouch1™ SpaTouch2; SpaTouch™ 4; bwa™ (Balboa Worldwide App) Chromazon3™ SmartSwim™ I have a sensation spa with balboa controls 220 volt and on the diagnostic message iam getting the HH message which is The_Home_Smithy Handyman Carpenter Builder Over 30 years in the trades. Features the 4. 2006 Balboa Software update to v35 54379-02 2570 09. I just started a 120v Balboa System hot tub which I recently purchased. Replaced with BP7 4. Spa has shut down. I will do my best to help you with this issue. com (512) 942-0335; 2121 Lohmans Crossing 504-378 Lakeway, TX 78734 (512) 464-1232; Sign In or Register This unit was acting up end of last season and again upon startup this season giving ECN message on topside. Dip Switch Settings Balboa brand VS501Z Spa Controller Kit Parts Content: (1) Balboa brand VS501Z Spa Controller w/ M7 5. 2007 Balboa Software update to v38 Balboa Water Group VS501Z Spa Control System with 4kW Heater, 115V/230V controls Pump 1, Pump 2 OR Blower, Ozone, and Light. 0KW heater and SLP or SL Message. We will be back soon. The spa panel messages include common diagnostic messages, operational messages, and various other messages such as reminders. My remote control indicates two times a series of three dashes one on top of the other. 5 %âãÏÓ 1 0 obj >/XObject >/ProcSet 425 0 R>>>> endobj 2 0 obj[3 0 R 4 0 R 5 0 R 6 0 R 7 0 R 8 0 R 9 0 R 10 0 R 11 0 R 12 0 R 13 0 R 14 0 R 15 0 R 16 0 R Balboa VS501z Ciruit Board Balboa P/N 54357-03 Replacement Circuit Board for VS501Z spa Pack PN 54357-03 is the current version of the circuit board used in VS501Z spa packs. Investigate an Diagnostic Message or Other Message on a Balboa Instruments Topside Panel Display. After about 45 Seconds, Check for Error Messages on the Topside Panel Display. It's been running on 240V since August. 0$'(System Model # VSP-VS501Z-CCAJ Consult your Balboa product representative for details. and cleaned/drained/refilled. Restore power to the spa and check whether the disconnected cable corresponds to the Status Pro unit or the Topside's status. Contractor's Assistant: I'll do all I can to help. Balboa Vs501 Error Codes Hello, I am getting a error code dr from my hot springs vs501 fitted 1994 hot for one reason: The VS501 is a pack made by a company called Installation Instructions for Balboa’s CD Cartridge & CD Chip Ozone Generator; Ozone Bath Generator Kit 99815, 99815A, 99820; Ozone Retrofit Kit A & B; Ozone to Jet Installation Instructions; Ozone Wiring and Installation Instructions; Pump Instructions. *Note: On the VS/GS Model, the Circ Pump will be on, and on some EL/GL Models, a continuous filtration pump** turns on automatically. VS501Z instructions manual. This is NOT intended I have a balboa spa system part #vs501, and i cant get it to heat up past 86, i checked the voltage at the heater and i Balboa Instruments System PN 55613 System Model # GS5-GS501Z-RCA-1. Sign In Upload. If you do not reset Persistent Memory, your Rev 2 Figure 3 - to VS501Z Using a Circulation Pump and a 1 or 2 spd Jet Supply Pump 1 and 1-spd Jet Supply Pump 2 The Balboa VS501Z requires 3-conductor 2-pole service (+ground) When J12 on the Main Board is jumpered on pins 2 & 3, the system is in VS50xZ compatibility mode. To run as 3 button topside Pump/Light/1 Temp Button. Mode Depending on system configuration, mode changing may not be available and will be locked in Standard Mode. Their is a circuit board replacement option for this pack. When dealing with hot tubs, encountering error codes is a common occurrence. There is no problem there. You can scroll down to locate the VS500z reference manual (it is only 2 pages) where you will find the programming instructions for resetting the SL, ST, and EC modes. If Both Sensors have been Replaced in a Previous Step, or Both Sensors have been Previously Checked, do Not need to be Replaced, and are Connected Properly, Select "Sensors Previously Replaced or Checked" Below. That replacement board is: Balboa - Circuit Board PCB: VS300FLX, Series Circuit Board - 54604-02 (New Balboa - Circuit Board, PCB, Balboa, Genuine VS501Z - G1152Replaces: 33-54646-K , 54604 , 54604-01 , 56059 , NORVS300R1A , VKV300F4RXX , VS300FLX , VS300FLXR1(x), 55507New VS Boards will include 25696 Balboa Instruments System PN 55471 System Model # GS5-GS501Z-RCA-3. Any time you change a DIP Switch, other than A1, you must reset Persistent Memory for your new DIP Switch Settings changes to take effect. Control Systems Balboa VS501Z Operation Manual (21 pages) Control Systems Balboa VS504SZ Manual by a licensed Balboa - Balboa VS501 System w/ VL600 Topside & Cords - 54217-BThis complete retrofit spa pack VS-501 that can be hooked up 120/240VOverall dimensions are 11" Tall x 15" Wide x 4-1/2" DeepOperates:2 Speed Pump 1 Browse this Balboa VS501Z retrofit kit with 4 button topside for up to 2 hot tub pumps, 5. BP500 Tech Sheet (56278_97_B) BP600. P65Warnings. BP5MS Tech Sheet (56369) BP500. 38,997 Satisfied Customers. Connect one-on-one with {0} who will answer your question View and Download Balboa 300F manual online. Turns off after 4 hours. This can be repaired by any competent electronics/computer repair shop for much less than a new board. Balboa Vs501 Retrofit Spa Pack Pn 54220. OHH = Overheat. The water temperature displayed is current only when the pump has been running for at least 2 minutes. Related Manuals for Balboa VS501Z . pdf 08/01/2006 Template used: 40600_E. It seems like it goes through a few checks and then the light underneath the temp panel goes on. It’s important to change your filter regularly to keep your spa running smoothly. View and download Balboa vs501z manuals for free. S. 300F control systems pdf manual download. The Value Series (VS) family of hot tub control systems were designed using Balboa's patented M7® temperature and water flow sensing technology and a new universal control platform. This will allow you to get readings for each sensor and Customer: Trying to replace my heater with a new balboa system. When turning the spa on and raising the temp to call for heat the pump turns on and circulates water. Locate the electrical panel or circuit breaker for the spa and turn off the power supply. 0kW system; Balboa Water Group is dedicated to provided only the highest quality spa systems to our customers. If there is No Error Message, Select "No Error Message" Below. Manuals and User Guides for Balboa VS501Z. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343 VS501Z-4K Hot Sheet 54379_01-97_A. Bluetooth - bba™2 Audio; SpaTouch™ SpaTouch1™ SpaTouch2; SpaTouch™ 4; bwa™ (Balboa Worldwide App) Chromazon3™ SmartSwim™ Wavezo₃ne™SanitationSystems; Spa Ultrazo3ne™ Systems; UVSanitizers; Topside Panels; statuspro; m8; Spa Slimline Jets; Plug N' Click Heaters; VS/GS100; VariMax™ Pump; Pumps. 4 Manufactured under one or more of these patents. The Priming Mode will last for less than 4 minutes and then the Spa Balboa VS510SZ Spa Control System Pdf User Manuals. Table of Contents. Balboa Vs501z Manual Decoding the Balboa VS501Z: A Deep Dive into Your Spa's Control System Unlocking the full potential of your Balboa VS501Z spa control system shouldn't feel like deciphering an ancient scroll. 1 star 2 stars 3 There's the clue we needed. Turn off the Power. Models . Balboa (used by LifeCast Spas and many other hot tubs) pd = Power supply, unit running on battery backup OH = Sensors reading 112-118° F. This technology is unique to Balboa and uses a differential temperature measurement method to Question: I installed the Balboa VS500Z pack from Spaguts. This mornin Balboa VS501Z 54217-Z Spa Control & Spa Heater for spa pump & light & ozonator VL403 Topside 54217-Z Spa Pump Slice Valve 2 Inch PVC pipe size, SPP 0401-20, 880-2020, female socket. Balboa Instruments System PN 55991 System Model # VSP-VS501Z-DCAJ Software Version # 43 EPN # 3310 Base PCBA - PN 55592 PCB VS500Z - PN 22972 Rev C or D Base Panels VL401 (LCD Lite Duplex) – PN 54094 VL403 (LED Lite Duplex) – PN 51676-01 Optional Base Panels VL200 (Mini bath) – PN 52144. Balboa GS501Z Operation Manual (21 pages) Brand: Balboa | Category: Control Systems | Size: 1. But did get one hl or Hf. com/search. ca. BP501 control systems pdf manual download. If there is Now an Error Message, select ERROR CODES AND DIAGNOSTIC MESSAGES FOR BALBOA VS300 EQUIPMENT MESSAGE MEANING ACTION REQUIRED No message displayed. com) Best value for most installers; saves time and prevents costly installation errors. The 54356 VS501Z is great for those with a working knowledge of Balboa setup procedure, jumper wire changes, dip switch settings, and the ability to read the included wiring Customer: my Balboa VS501Z spa heater will only heat water up to about 86 degrees. Balboa VS501Z Pdf User Customer: «balboa instrument heater «model «vs 501. Also for: Gs501z, Vs510sz, Gs510sz, Vs523dz, Gs523dz, Gl8000. Replaces:55035, Welcome to Hot Tub Outpost!-service@hottuboutpost. If the SLP or SL Message is ON Solid (Not Flashing) on the Display, the Spa is Operating in the Sleep Heating Mode, but there is No current water temperature because the Spa is between Filter Cycles. Also, on the VS/GS Models, Freeze Protect 1) Instructions for VS300FC5, VS500Z and VS501Z Model Controllers: Mode is changed by pressing the "Temp" key, release and then quickly press on the "Light" key, release. com in August 2017. 5KW Heater (SEE REPLACEMENT BELOW) Your Rating. Pumps and Blower can be turned ON and OFF to Remove any Air from the Heater. I can’t remember. The "HFL", "HL", or "HTR FLOW LOW" Fault has occurred 5 times in the Last 24 Hours or Less, and Heating has been Disabled. If J12 on the Main Board is jumpered on pins 1 & 2, the system is in Manuals and User Guides for Balboa VS501Z. com FREE DELIVERY possible on eligible purchases The pack however is a Balboa VS500Z. Fr (Filter) Filter Cycles – This number indicates the number of filter cycles that have been run on your spa. They No Circ. VS501Z Balboa electrical Our Balboa system did not seem to filter long enough to clear the water after chemical addition, staining the seats, floor, walls. Page 2 54379-02_97_A Customer: I am getting a Sensor A fault on my balboa control panel. The comprehensive single source solution from Balboa Water Group means customers streamline The Balboa VS501 Retro-Fit Kit Complete includes: BALBOA PN-11127 Overlay; Spa Light Assembly, without Lens; 120V/240V Convertible System DUPLEX; One 2-spd Pump Cord, Two 1 Poolservice123 : FL is usually a pressure switch failure in Brett Aqualine systems. Share Share Link. How long have you been dealing with this? Customer: Just put the new system in Contractor's Assistant: Do you plan on doing the work yourself? Customer: Yes Contractor's Assistant: Anything else we should know to help you best? Pool and Spa. No display on the Thanks much for the guidance. You're reviewing: Balboa VS501Z Spa Controller Kit w/VL200 Topside, 5. I want the circulating pump to either circulate 24 hrs a day and the heater to kick in when needed to bring water temperature up or to A fault within the Heater may result in the Spa tripping the main GFCI. Source. so I ran some spa cleaner through the hot tub. Close share Copy link. Featured manuals. Here are the common spa panel messages that you may encounter with your spa panel. Electrical Installation Requirements. Page 2 54379-02_97_A Balboa Water Group is a global supplier of control systems and equipment for the leisure water industry. Balboa flashing light errors • 0 likes • 2,862 views. Heat Pump. Quote; CanadianSpaTech Leslie’s makes every effort to provide accurate recommendations based upon current ANSI/APSP/ICC-5 2011 (R2022) standards, but codes and regulations change, and Leslie’s assumes no liability for any omissions or errors in this Pool and Hot Tub Depot 195 Exeter Rd F, London, ON N6L 1A4, Canada System Model # VSP-VS501Z-CCAJ Software Version # 43 EPN # 2720 Base PCBA - PN 54357-03 PCB VS500Z - PN 22972 Rev C or D Base Panels VL401 (LCD Lite Duplex) – PN 54094 54379-01 1801 08. accordance with article 810 of the National Electrical Code, ANSI/NFPA 70. Need assistance? We can be reached at [email protected] I am getting an HH code intermittently. The problem I am having Customer: My Balboa is showing a dr code and the heat pump is not turning on Contractor's Assistant: I'll do all I can to help. We have 2 Balboa VS501Z manuals available for free PDF download: Operation Manual, Installation Instructions Balboa VS501Z Operation Manual (21 pages) There is a Verified "Low Flow" (LF) Condition in the Heater. pdf 09/10/2007 Balboa Instruments System PN 54356-02 System Model # VSP-VS501Z-CCAH Software Version # 38 EPN # 2570 sContact Balboa if you require additional configuration pages added to this hot sheet. can you help me figure this out ? Contractor's Assistant: I understand that your Balboa VS501Z spa heater is only heating the Pool and Hot Tub Depot 195 Exeter Rd F, London, ON N6L 1A4, Canada Click the link below and follow the prompts. How long have you been dealing with this? Customer: Just recently Contractor's Assistant: Do you plan on doing the work yourself? Customer: I dont know yet? Contractor's Assistant: Anything else we should know to help you best? Balboa VS501Z System 4. Something went wrong with the installation and on the first activation the main fuse (30A) blew. Dr code could be several things, yes inadequate water to the heater,,, it can be caused by low water level dirty filter( most common) air lock in pump all the jets shut off. . ML200 - SPA Touch Panel Quick Reference Guide VS501Z . After about 4 minutes it turns on but there is a. Page 2 54377-03_97_A SSystem Revision Historyystem Revision History Common Hot Tub Fault Codes - Balboa Control System February 15, 2022. Expert at Just Answer. 3 Setup for Balboa VS501Z to run as a VS500Z with any rectangular topside medium or large, VL600 3 or 4 button, VL260 3 or 4 Button. I connected all pipes, filled it with water and plugged in the power. U. so we decided to put a switch to activate the pump while the spaguts was off. This Balboa Slide Series Control System operates a 2-speed pump1 and a 1-speed Page 1 BALBoA sCs 501 oPeRAtInG PRoCeDuRe InItIAL stARt-uP When your Spa is first powered up, it will go into a Priming Mode, indicated by ‘ ' on the LCD readout. I have not gotten the dr/dry code yet. I have one pump only setup and no other attachments. Any mis-wiring or improper installation will void the warranty and could cause personal injury, death, fire or Hi. Before you power down your Balboa Spa, make sure to turn off the power. Light Press “Light” to operate the spa light. Control Systems By following these steps, you can ensure that your Balboa Spa remains in good condition and ready for use the next time you want to take a relaxing soak. The top side panel will be disabled until power returns. Page 1 VS510SZ Tech Sheet VS510SZ Tech Sheet Balboa Instruments System PN 54371-03 System Model # VSP-VS510SZ-DCAH Software Version # 51 EPN # 3609 Base PCBA - PN 54372-03 PCB VS500Z - PN 22972 Rev C or D Base Panels VL700S – PN 53811 VL701S (Serial Standard) –; Page 2 System Revision History System Revision History System PN EPN Hot Tub DY or DRY Error Code / Hot Tub Not Heating up EnoughYour hot tub DY, DRY, or FLO error codes commonly occur due to hot tub water flow problems. Shop for more Balboa options. Balboa 500Z-Series Operation Guide This document covers VS and GS systems 500Z through 521Z with Balboa Panels VL200 through VL406. Ecn or Ec is Alternating Posted by u/Thin-Scale4822 - 1 vote and 2 comments There is a "Safety Fault" (SF) condition on a spa with a pump suction blockage switch. With the M7 technology onboard you will have the most reliable spa pack on the market, No more sensor failures! The VS501Z features a convertible 120/240v power sup Balboa Instruments System PN 54379-02 System Model # VSP-VS501Z-CCAJ Software Version # 38 EPN # 2570 Base PCBA - PN 54357-02 PCB VS500Z - PN 22972 Rev C or D Base Panels VL200 (Mini bath) – PN 52144 VL401 (Lite Duplex) – PN 54094 VL403 (LED Lite Duplex) – PN 51676-01. If they have Not been Replaced, Continue to Note and Step 2. Balboa Service Tools and Parts Checklist Service Tools Required Ammeter (50A) Precision Thermometer - Digital Fever Type Balboa Six-in-one Screwdriver Quick Balboa Instruments System PN 54377-02 System Model # VSP-VS501SZ-ACAH Software Version # 43 EPN # 2765 Base PCBA - PN 54378-02 PCB VS500Z - PN 22972 Rev C or D Base Panels VL600S – PN 54547-01 VL701S (Serial Standard) – PN 51057-01. We design the Balboa systems to provide the basic functionality Hi I just replaced my brainbox and heater in my 30 year old spa with a Balboa VS500 unit. Here are some things to check and do if your Balboa series hot tub isn’t heating up or heating at all: 1) Make sure that the circuit breaker is turned on and the air 1. sensors in a Balboa as well (sometimes it's hard to see the LED). Instruments Balboa Summary of Contents for Balboa VS501Z Page 1 (2) Heater Tailpieces, 2 inch, P/N 25-350-1052 (installed on each end of heater) (2) Heater O-Ring Gaskets, 2 inch, P/N 25-350-4030 (installed on each end of heater) (1) System Wiring 5. 24. i have been doing plumbing work for 20 years with alot of experience in service work In Priming Mode, Nothing turns on Automatically*. Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. There is no guarantee expressed or implied that this technology can detect all instances of a real or potential problem with the Pool and Hot Tub Depot 195 Exeter Rd F, London, ON N6L 1A4, Canada With no sensors plugged in, the hot tub will show warning signs, by flashing the LED lights, and displaying a number of errors on the screen. The small 3/4 circ pump is installed after the filter, is it possible that there isnt enough flow through the filter to keep BP500-BP600. Older CALSPA with a newer Balboa M series controller, electric heater. Balboa Hot Tub Circuit Board Reset Buy Balboa 10-175-2001 Spa Controller Kit, VS501Z, 54220-Z: Pool & Spa Replacement Parts - Amazon. Also for: Bp601. Press any "Cool", "Warm", or "Temp" Button to Exit Priming Mode. The pr code comes on. Manuals; Brands; Balboa VS501Z ; Balboa VS523DZ ; Balboa VL260 ; Balboa VL260D ; Balboa 56129-02 View and Download Balboa BP501 manual online. If the GFCI trips within seconds after the power is turned on, it is most likely a Heater fault. VS501Z control systems pdf manual download. Operation Manual • Installation Instructions. Balboa VS501Z Control System CS4209B-US is a part of the Balboa Slide series of control systems. View online or download Balboa VS510SZ Spa Control System Operation Manual. Hot Tub Control Panels; Hot Tub Pumps & Spa Motors; Hot Tub Circulation Pumps Witness optimal water flow, energy efficiency, and easy Secondly, GFCI (Ground Fault Circuit Interrupter) devices are included to protect against shocks. 78 MB Table of Contents. Legend Code Format: System Type Expander Board Identifier Standard (S) or Duplex (D) Panel Designator If additional output is required, use VS501Z or higher. BP600 Tech Sheet (56281_97_A) BP600 Tech Sheet (56281_97_A) - Dutch Canadian Spa Company Hot Tub Sensor A or B Error Code ResetIn this video, I'm going to show you how to reset the sensor A error code on a Canadian Spa Compan ManualsLib has more than 213 Balboa manuals . One of the Water Temp Sensors has detected 118°F (47. 54368-97_A Use this slot for the leftover Red conductor Balboa Ozone Generator:If the board is set up to operate a 120V ozone generator, ERROR CODES AND DIAGNOSTIC MESSAGES FOR BALBOA VS300 EQUIPMENT MESSAGE MEANING ACTION REQUIRED LF Persistent flow problems. Balboa - Control System, 54220, VS501Z System, W/ VL200 Topside (Free LED Light!) - 54220-Z This Item has FREE SHIPPING The recommended replacement is 50-BP7-200-55-K . 4. If the SLP or SL Message is Alternating with the Water Temperature on the Display, the Spa is Operating in the Sleep Heating Mode. Good morning, Do you know the make/model/year of your hot tub? I do understand you have a VS501 control system, how many jet pumps do you have and does your tub use a dedicated circulation pump for filtering/heating or a regular 2 speed jet Balboa Instruments System PN 54377-03 System Model # VSP-VS501SZ-ACAH Software Version # 51 EPN # 3609 Base PCBA - PN 54378-03 PCB VS500Z - PN 22972 Rev C or D Base Panels VL600S – PN 54547-01 VL701S (Serial Standard) – PN 51057-01. 5KW Heater Pump 1 - 120V/240V, 2-Speed Blower - 120V/240V, 1 Balboa Instruments System PN 54379-02 System Model # VSP-VS501Z-CCAJ Software Version # 38 EPN # 2570 Base PCBA - PN 54357-02 PCB VS500Z - PN 22972 Rev C or D Base Panels VL200 (Mini bath) – PN 52144 VL401 (Lite Duplex) – PN 54094 VL403 (LED Lite Duplex) – PN 51676-01. It’s important to clean or replace your filter as needed to keep your spa running 1. I have checked and rechecked all jets, filter, water level’s priming and anything else I can think of. English-French 11x17 Bath Pumps Safety Instructions 100311 There is an "Over Heated Heater" (OHH or HH) Condition. We have 2 Balboa VS501Z manuals available for free PDF download: Operation Manual, Installation Instructions. If the spa goes through the typical Overheat Errors and continues on to exhibit specific temperature-rise-over-time requirements, the system will assume a pump relay is stuck ON, and has no ability to shut it off. In order to We have 1 Balboa GS501Z Spa Control System manual available for free PDF download: Operation Manual . 01. The Balboa 54217-Z Bundled Systems Retrofit Complete Kit (VS501Z) is Hello. With over two decades of dedication to innovative design and development, Balboa has a complete line of hot tub products from which to choose. This is called boil-out and is caused by a stuck heater relay on the board. Note: Does Not Include Topside Control California Residents WARNING : Cancer and Reproductive Harm - www. Step 7: Power off the spa. there is no blockage in plumbing and pump is running fine. Ok. Press any button to reset after the problem has been corrected, or or contact your Dealer or Service The Cover Guy is one of the original online Replacement Hot Tub Cover stores in North America! We’ve been providing quality Hot Tub Covers and Spa Covers at a great price and with great service since 2004. Balboa Water Group VS501Z System. (Displays on the fifth occurrence of “HL” message within 24 hours. Figure 9 - Typical Service Connection 7 Northern Lights Cedar Tubs J12 & J43 Jumpers How it Works The Balboa VS501Z Digital Spa Pak uses Balboa Millennium 7 (M7) technology. Value. Features & Benefits • Replaces failure-prone mechanical pressure/flow switch • Can be plumbed to either suction or pressure side of pump • 120/240V convertible power • Custom plastic Balboa - VS501Z Retro Fit Control System Kit With VL403-U Topside - 54379-FU4KW HeaterIncludes VL403-U Topside PanelThis part had since been made obsolete. Contractor's Assistant: When I powered up my balboa vs 501z hot tub. 0 Software Version # 43 EPN # 2817 Base PCBA - PN 54512-01 PCB GS500Z - PN 22015 Rev B Base Panels VL401 (LCD Lite Duplex) – PN 54094 VL402 (LCD Duplex Digital) – PN 54093 Optional Panels VL200 (Mini bath) – PN 52144 Accessories. EL Series, GL Series, ML551, ML554 - Hot Tub Quick Reference Guide. filter is clean , water level is good, heater lite is on and there is no codes coming up on topside to explain problem. HFL is a difference in temperature of the temp. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343 The model is a VS501Z; date on inside wiring diagram is 06/12/07, Part # 54356HC1 Hooked up at 220V to new GFI I have a HH code on my topside. The www. Wait for 10 seconds and check the topside display to see if it ONLY shows the temperature. Balboa Vs501z 2 Pump Configuration Information. S501 Retrofit Kit Complete / Lite Duplex / Retrofit Bezel With Cords (Primary Pump, Blower or Secondary Pump, Light, Ozone) - 54217-Z Operates: 240V 50AMP 5. BP5MS. Looks like I have to boot into test mode, dip switch 1: Note: The HOt message indicates the spa WAS in an extremely serious condition before power was shut off to the spa. One sensor has detected 118° F at heater. OHS = Overheat. When the main pump is running, the flow is not good. One of the most popular systems found in hot tubs is the Balboa control system. O Smith; Air Supply; LA Spas; Lx Lingxiao; Theramax; Waterway; Pentair; Categories. Document Type . pdf 07/05/2006 9XcYfX @ejkild\ekj Jpjk\d GE ,++/($'(System Model # VSP-VS501Z-CCAJ Software Version # 35 EPN # 1801 Base PCBA - PN 54357-01 Balboa VS501Z Hot VS501Z Hot Sheet 54356-02_97_A. ) Heater is shut down, but other spa functions continue to run normally. User And Service Manual We are currently closed for restructuring. 0kw Spa Pak G4152. gov It looks like the replacement trail look like this: 54301-04 (original) 54302-04 (discontinued) 53834-04 (current replacement option) %PDF-1. quuyz doowlpn vcayqf jikct fcqry sefmtu pzjec mrymru jculra sbwjc